Technical Specification
Model Number FST-500 | 007 | 015 | 022 | 037 | 055 | 075 | ||||||||
Max. Applicable Motor Output (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | ||||||||
Max. Applicable Motor Output (HP) | 1.0 | 2.0 | 3.0 | 5.0 | 7.5 | 10 | ||||||||
Output rating rating | Rated Output Capacity (kVA) | 2.3 | 3.1 | 3.8 | 6.2 | 9.9 | 13.7 | |||||||
Rated Output Current (A) | 3.0 | 4.0 | 5.0 | 8.2 | 13 | 18 | ||||||||
Maximun Output Voltage (V) | 3-Phasc Proportional to input voltage | |||||||||||||
Output Frequency (Hz) | 0.1 ~400Hz | |||||||||||||
Carrier Frequency (kHz) |
|
| 1- | 15 |
|
| ||||||||
Input rating | Rated Input Current (A) | 3-Phasc | ||||||||||||
4.2 | 5.7 | 6.0 | 8.5 | 14 | 23 | |||||||||
Rated Voltage. Frequency | 3-Phaso 380 to 480V . 50 / 60Hz | |||||||||||||
Voltage Tolerance | ± 10%(342~528V) | |||||||||||||
Frequency Tolerance | ± 5%(47—63Hz) | |||||||||||||
|
| Fan Cooled | ||||||||||||
Weight (Kg) | 1.5 | 1.5 | 2.0 | 3.2 | 3.2 | 3.3 | ||||||||
Control characteristics | Control System | SPWM (Sinusoidal Pulse Width Modulation)control (V/F or sensorless vector control) | ||||||||||||
Freq. Setting Resolution | 0.1Hz | |||||||||||||
Output Frequency Resolution | 0.1Hz | |||||||||||||
Torque Characteristics | Including the auto-torque, auto-slip compensation; starting torque can be 150% at 5.0Hz | |||||||||||||
Overload Endurance | 150% of rated current for 1 minute | |||||||||||||
ISkip Frequency | Three zones, settings range 0.1-400Hz | |||||||||||||
|Accel/Decel Time | 0.1 to 600 seconds (2 independent settings for Accel/Decel Time) | |||||||||||||
Stall Prevention Level | 20%-200%, Setting of Rated Current
| |||||||||||||
DC Injection Braking | Operation frequency 0-60Hz, output 0-100% rated current | |||||||||||||
Braking Torque | Approx. 20% (up to 125% possible with option braking resistor or | |||||||||||||
V/F Pattern | Adjustable V/F pattern | |||||||||||||
Operating characteristics | Frequency | Keypad | Set by®® | |||||||||||
External | Potcntiometcr-5KQ/0.5W, 0 to +10VDC; 4 to 20mA, RS-485 interface; | |||||||||||||
Operation Setting Signal | Keypad | Set by RUN, STOP | ||||||||||||
External | 2 wires / 3 wires (Run, Stop, Forward / Rev, ), JOG operation, | |||||||||||||
Multi-Function Input Signal | Multi-step selection 0 to 7, Jog. accel/decel inhibit, first to forth accel/decel switches, counter, | |||||||||||||
Multi-Function Output Indication | AC Drive Operating, Frequency Attained, Non-zero, Base Block, Fault Indication, | |||||||||||||
Analog Output Signal | Analog frequency/current signal output. | |||||||||||||
Alam Output Contaact | 1Form C contact or open collector output. | |||||||||||||
Operation Functions | AVR. S-Curve. Over-Voltage. Over-Current Stall Prevention, Fault Records. Adjustable Carrier |
![]() |
ANYHERTZ DRIVE (SHENZHEN) CO., LTD.
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Ltd. |